64.6.2 Connecting to YOKOGAWA PLC (STARDOM)

System Configuration
YOKOGAWA
PLC
Connection cable
PLC
Connection cable
Commu
Model
nication
Cable model
type
• 10BASE-T
Shielded twisted
pair cable (STP)
or
Unshielded twisted
pair cable (UTP)
*1
Ethernet
STARDOM
Category 3, 4, and 5
• 100BASE-TX
Shielded twisted
pair cable (STP)
Category 5 and 5e
*1
When connecting STARDOM to MODBUS
For details, refer to the following manual.
*2
To connect a GOT to a PLC, connect to the PCL Ethernet port via a hub.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standard.
*3
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
*4
Use the straight cable.
The use of shielded twisted pair cable (STP) is recommended in environments in which the performance against noise is required.
*5
Use C or later version of GT11H-C-37P.
PLC side setting
Make the communication settings as shown below. For
details of the communication settings, refer to the
peripheral software manual for YOKOGAWA PLC.
POINT
POINT
POINT
Connection between STARDOM and the PC for
communication settings
For the communication settings of STARDOM,
STARDOM and the PC for communication settings
must be connected to Ethernet using the Resource
Configurator (peripheral software).
Hub
Connection cable
*4
Connection cable
External
Maximum
device
segment
Cable model
length
• 10BASE-T
Shielded twisted
pair cable (STP)
or
Unshielded twisted
pair cable (UTP)
*3
*2
100m
Hub
Category 3, 4, and 5
• 100BASE-TX
Shielded twisted
pair cable (STP)
Category 5 and 5e
/TCP, Modbus Communication Portfolio License is required.
YOKOGAWA PLC user's Manual
Connector
conversion
box
External cable
*4
Connector
Maximum
conversion
External cable
segment
box
length
GT14H-C30-42P (3m)
GT16H-
GT14H-C60-42P (6m)
CNB-42S
GT14H-C100-42P(10m)
*3
100m
GT11H-C30-37P (3m)
GT16H-
GT11H-C60-37P (6m)
CNB-37S
GT11H-C100-37P(10m)
(1) Modbus Communication Portfolio License
To set the communication settings for STARDOM, an
installation of Modbus Communication Portfolio License
is required.
For details on the communication settings, refer to the
following manual.
STARDOM FCN/FCJ Guide
64. MODBUS(R)/TCP CONNECTION
64.6 Example of Connection
Communication driver
MODBUS/TCP
GOT
Number of
GOT
*5
connectable
model
equipment
126 GOTs
for 1 PLC
64 - 7