1J-6 Charging System:
9) Loosen the generator rotor bolt.
NOTE
When loosen the rotor bolt, do not remove it.
The rotor bolt is used in conjunction with the
rotor remover when removing the rotor.
10) Remove the generator rotor assembly with the
special tool.
NOTE
Remove the starter clutch if necessary. Refer
to "Starter Torque Limiter / Starter Clutch
Removal and Installation in Section 1I
(Page 1I-10)".
Special tool
(A): 09930–30721 (Rotor remover)
11) Remove the key (6).
6
12) Remove the generator stator (7) along with the CKP
Installation
Install the generator in the reverse order of removal. Pay
attention to the following points:
• Tighten the generator starter set bolts (1) and CKP
I940H11A0008-01
(A)
I940H11A0009-01
I940H11A0010-01
sensor (8).
7
sensor mounting bolts (2) to the specified torque.
NOTE
Be sure the grommet (3) is set to the
generator cover.
Tightening torque
Generator stator set bolt (a): 11 N·m (1.1 kgf-m,
8.0 lbf-ft)
CKP sensor mounting bolt (b): 5.5 N·m (0.55 kgf-
m, 4.0 lbf-ft)
1
(a)
8
I940H11A0011-02
3
2
(b)
I940H11A0002-02