Suzuki Intruder VZ1500 Service Manual page 161

Hide thumbs Also See for Intruder VZ1500:
Table of Contents

Advertisement

Step
1
1) Turn the ignition switch OFF.
2) Remove the seat. Refer to "Exterior Parts Removal and
Installation in Section 9D (Page 9D-5)".
3) Check the EVAP system purge control valve coupler (1)
for loose or poor contacts.
If OK, then measure the EVAP system purge control
valve resistance.
4) Disconnect the EVAP system purge control valve
coupler.
5) Measure the resistance between terminals.
Special tool
(A): 09900–25008 (Multi-circuit tester set)
Tester knob indication
Resistance (Ω)
EVAP system purge control valve resistance
Approx. 32 Ω at 20 °C (68 °F)
(Terminal – Terminal)
Is the resistance OK?
Action
1
(A)
Engine General Information and Diagnosis:
Yes
Go to Step 2.
I940H1110087-01
I940H1110088-02
1A-94
No
Replace the EVAP
system purge control
with a new one. Refer to
"Evaporative Emission
Control System
Removal and
Installation (Only for E-
33) in Section 1B
(Page 1B-11)".