Siemens SINUMERIK 828D Operating Manual page 784

Computerized numerical controller for machine tools
Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

Managing programs
13.18 RS-232-C
V24 setting
End of data transfer (hex)
Time monitoring (sec)
Procedure
784
Meaning
Only for punched tape format
Stop with end of data transfer character
The default setting for the end of data transfer character is (HEX) 1A
Time monitoring
For data transfer problems or at the end of data transfer (without end
of data transfer character) data transfer is interrupted after the speci-
fied number of seconds.
The time monitoring is controlled by a time generator (clock) that is
started with the first character and is reset with each transferred char-
acter.
The time monitoring can be set (seconds).
1.
Select the "Program Manager" operating area.
2.
Press the "NC" or "Local drive" softkey.
3.
Press the ">>" and "Archive" softkeys.
4.
Select the "V24 settings" softkey.
The "Interface: V24" window is opened.
5.
The interface settings are displayed.
6.
Press the "Details" softkey if you wish to view and process addi-
tional settings for the interface.