Fail-Count - Allied Telesis AT-AR3050S Command Reference Manual

Next-generation firewall
Hide thumbs Also See for AT-AR3050S:
Table of Contents

Advertisement

P
-P
C
ING
OLLING
OMMANDS
-
FAIL
COUNT

fail-count

Overview
This command specifies the number of pings that must be unanswered, within the
total number of pings specified by the
instance to consider the device unreachable.
If the number set by the
the same, then the unanswered pings must be consecutive. If the number set by
the
command, then a device that does not always reply to pings may be declared
unreachable.
The no variant of this command resets the fail count to the default.
fail-count <1-100>
Syntax
no fail-count
Default
The default is 5.
Mode
Ping-Polling Configuration
Examples
To specify the number of pings that must fail within the sample size to determine
that a device is unreachable for ping-polling instance 45, use the commands:
awplus#
awplus(config)#
awplus(config-ping-poll)#
To reset the fail-count to its default of 5 for ping-polling instance 45, use the
commands:
awplus#
awplus(config)#
awplus(config-ping-poll)#
Related
critical-interval
Commands
normal-interval
ping-poll
sample-size
show ping-poll
timeout (ping polling)
up-count
C613-50077-01 REV A
sample-size
command is greater than the number set by the fail-count
Parameter
Description
<1-100>
The number of pings within the sample size that a reachable device
must fail to respond to before it is classified as unreachable.
configure terminal
ping-poll 45
configure terminal
ping-poll 45
Command Reference for AT-AR3050S
AlliedWare Plus™ Operating System - Version 5.4.5-2.x
sample-size
sample-size
command and the fail-count commands are
fail-count 5
no fail-count
command, for the ping-polling
2078

Hide quick links: