SAN end-to-end monitoring

TABLE 85
Counter name
Current
Rx Power
Tx Power
Invalid Oredered Set
BB Credit Zero
Truncated Frames
FEC Corrected Blocks
FEC Uncorrected Blocks
Latency
Dropped Packets
Link Retransmits
Timeout Retransmits
Fast Retransmits
Duplicate Ack Received
Window Size RTT
TCP Out of Order Segments FCIP
SlowStart Status
CRC Errors
SAN end-to-end monitoring
Procedures in this section pertain to end-to-end monitoring using the legacy End-to-End Monitor
feature instead of using Flow Vision to create end-to-end monitors.
For systems using Fabric OS version 7.2 or later, when you select a device or device port, and then
select Monitor > Performance > End-to-End Monitors, a message displays that you can use Flow
Vision to provide End-to-End monitoring. You have these options:
Refer to the following important notes when using this feature:
1090
Performance counters
Type
FC
FC
FC
FC
FC
FC
FC
FC
FCIP
FCIP
FCIP
FCIP
FCIP
FCIP
FCIP
FCIP
EE Monitors
To use Flow Vision, delete existing monitors, then use the Add Flow Definition dialog box to
define an initiator and target port pair for monitoring. Refer to
more information.
Clicking OK, opens the legacy Set End-To-End Monitors dialog box.To use the legacy End-to-End
Monitor feature, you must deactivate existing flows defined for the switch for Flow Vision.
For systems using Fabric OS version 7.2 or later, you can create end-to-end monitors using the
Flow Vision feature. Refer to
End-to-end monitoring requires a Fabric OS device.
An end-to-end monitor and a Top Talker monitor cannot be configured on the same fabric or
external F_Port application-specific integrated circuit (ASIC). You must delete the Top Talker
monitor before you configure the end-to-end monitor.
Protocol
Source OID value
SNMP
.1.3.6.1.4.1.1588.2.1.1.1.28.1.1.3
SNMP
.1.3.6.1.4.1.1588.2.1.1.1.28.1.1.4
SNMP
.1.3.6.1.4.1.1588.2.1.1.1.28.1.1.5
SNMP
.1.3.6.1.3.94.4.5.1.45
SNMP
1.3.6.1.3.94.4.5.1.8
SNMP
1.3.6.1.3.94.4.5.1.47
SNMP
1.3.6.1.4.1.1588.2.1.1.1.27.1.31
SNMP
1.3.6.1.4.1.1588.2.1.1.1.27.1.32
SNMP
.1.3.6.1.4.1.1588.4.1.1.5
SNMP
.1.3.6.1.4.1.1588.4.1.1.3
SNMP
.1.3.6.1.4.1.1588.4.1.1.2
SNMP
.1.3.6.1.4.1.1588.4.1.1.9
SNMP
.1.3.6.1.4.1.1588.4.1.1.10
SNMP
.1.3.6.1.4.1.1588.4.1.1.11
SNMP
.1.3.6.1.4.1.1588.4.1.1.12
SNMP
.1.3.6.1.4.1.1588.4.1.1.13
SNMP
.1.3.6.1.4.1.1588.4.1.1.14
HTTP
PortCRC (variable from the return html file)
Chapter 29, "Flow Vision"
Chapter 29, "Flow Vision"
for details.