Brocade Communications Systems WFT-2D User Manual page 1309

San user manual
Table of Contents

Advertisement

2. Select the Enable E-mail Event Notification check box to enable the application to send e-mail
3. Enter the IP address or the name of the SMTP mail server that the server can use to send the
4. Select the SMTP over SSL check box to enable secure communication.
5. Enter the port number of the SMTP mail server in the SMTP Port field.
6. Enter the authentication ID of the SMTP mail server in the SMTP ID field.
7.
8. Enter the sender's e-mail address in the Reply Address field.
9. Enter the length of time the application should wait between notifications in the Summary
10. Select one of the following e-mail test options:
11. Click Send Test E-mail to test the e-mail server.
12. Click OK to save your work and close the E-mail Event Notification Setup dialog box.
Brocade Network Advisor SAN User Manual
53-1003154-01
messages in case of event notifications.
e-mail notifications in the E-mail Server field.
The Management application accepts IP addresses in IPv4 and IPv6 formats. The IPv4 format
is valid when the operating system has IPv4 mode only or dual stack mode. The IPv6 format is
valid when the operating system has IPv6 mode only or dual stack mode.
If SMTP over SSL is not enabled, the default is 25.
If SMTP over SSL is enabled, the default is 465.
NOTE
The SMTP ID field is optional unless the SMTP server enables authentication.
Enter the authentication password of the SMTP mail server in the SMTP Password field.
NOTE
The SMTP Password field is optional unless the SMTP server enables authentication.
Interval field and list.
Notifications are combined into a single e-mail message and sent at each interval setting. An
interval setting of zero causes notifications to be sent immediately.
ATTENTION
Setting too short an interval can cause the recipient's e-mail inbox to fill very quickly.
Select Send to and enter an e-mail address for a user to send a test e-mail message to a
specific user.
Select Send to all users enabled for notification to send a test e-mail message to all users
already set to receive notification.
A message displays whether the server was found. If the server was not found, verify that the
server address was entered correctly and that the server is running. If you are using an SMTP
mail server, also verify that the SMTP ID and password information was entered correctly.
32
Event notification
1257

Advertisement

Table of Contents
loading

This manual is also suitable for:

Network advisor 12.3.0

Table of Contents