Brocade Communications Systems WFT-2D User Manual page 1295

San user manual
Table of Contents

Advertisement

7.
Brocade Network Advisor SAN User Manual
53-1003154-01
The selected fabrics display in the Selected Fabrics list.
To set configuration policy managers for switches, select the Switch/Router Checks tab
(Figure
531) and complete the following steps.
FIGURE 531
Add Configuration Policy Manager dialog box, Switch/Router Checks tab
a. Select one or more of the following checks in the Available Checks list to include them in
the configuration policy manager:
For more information about these checks and fixes for rule violations, refer to
router configuration policy managers"
Select the Check if the product is configured to send events to this server to
determine if the Management application server is registered as an SNMP recipient
and syslog recipient.
Select the Check for redundant connections to neighboring switches (SAN only) check
box to determine if there are at least the minimum number of configured ISLs
between each switch pair.
Select the Check for HTTPS (secure HTTP) configuration check box to check each
target to see if HTTPS is active for device data transmission.
Select the Check if the product is configured to send Upload Failure Data Capture to
an FTP server (SAN only) check box to determine the following configurations:
– Upload Failure Data Capture is enabled on the selected switches.
– A configured FTP Server is accessible.
– You have write permission to the directory.
Select the Check for SSH (secure Telnet) configuration check box to check each target
to see if SSH is enabled for device data transmission.
Adding a configuration policy manager
on page 1233.