Brocade Communications Systems WFT-2D User Manual page 1208

San user manual
Table of Contents

Advertisement

29
Flow Monitor
5. Select the Activate all selected features check box to immediately activate the flow after
6. Enter * in the Source and Destination fields to monitor frames on the ingress port (30)
7.
8. Select OK to save the definition.
Configuring an end-to-end monitor flow
You can use the Bidirectional option to create the equivalent to an end-to-end monitor. The
following example creates a bidirectional Flow Monitor flow between device 02d8c0 and device
023a00 egressing port 4/10 of the switch on which the flow is running.
1. Right-click an egress port (4/10) on the device and select Fabric Vision > Flow > Add.
2. Enter a name (EndtoEndMonitor) for the flow definition in the Name field.
3. Select the Persist over switch reboots check box to persist this flow definition over reboots.
4. Select the Activate all selected features check box to immediately activate the flow after
5. Enter the address or WWN of the source port (023a00) in the Destination field.
6. Click OK.
7.
1156
creation.
between all devices.
Click OK.
The Flow Vision dialog box displays with the new flow definition highlighted.
When the flow definition activates, the Flow Vision dialog box displays with the new flow
selected (highlighted) in the Flow Definitions table. To review the sub-flow data for the selected
flow (refer to
"Monitoring a Flow Monitor flow"
The Add Flow Definition dialog box displays with the following criteria and flow identifiers
pre-populated:
Feature — Monitor
Direction — Bidirectional
Source Device — Source identifier (02d8c0)
Destination Device — * (an asterisk allows you to use any port)
Ingress port — port number (30)
The name cannot be over 20 characters and can only include alphanumerics or underscores.
NOTE
For a physical switch, the name must be unique. However, for logical switches, the name does
not have to be unique.
creation.
The Flow Vision dialog box displays with the new flow definition highlighted.
Select OK to save the definition.
When the flow definition activates, the Flow Vision dialog box displays with the new flow
selected (highlighted) in the Flow Definitions table. To review the sub-flow data for the selected
flow, refer to
"Monitoring a Flow Monitor flow"
on page 1149").
on page 1149".
Brocade Network Advisor SAN User Manual