28
SAN connection utilization
5. In the Time Range area, select one of the following options:
1118
(Historical graphs and monitors only) Plot Min/Max - Plots minimum and maximum values
along with the average data. The range between the minimum and maximum values will
be represented by the width of a color band surrounding the data points as shown in the
following illustration. Note that this option is not available if you select Minimum Interval
granularity. It also does not apply and is not available for real-time performance graphs.
FIGURE 492
Show events - Select to display advanced monitoring service (AMS) violation events
received during the chart time range and master log events logged on the same product as
the measure being plotted. Each event will be represented by the same severity icon that
is shown in the master log (refer to the icons at the bottom of the following graph). Pausing
the pointer over the icon displays details of the violation, such as violation time,
switch/port information, violated rule name, and violated rule condition. Monitoring and
Alerting Policy Suite (MAPS) violations are plotted for a product or port level measure
(whichever is selected) during the plotted time range. The show events graph is shown in
Figure 687
on page 1744.
FIGURE 493
Select Relative time to set a time range relative to the present for the display of historical
data.