Avaya DEFINITY Server CSI Maintenance Manual page 886

Table of Contents

Advertisement

Maintenance Objects
Receive FIFO Overflow Error Counter Test (#596)
This test is non-destructive. When the CLAN circuit pack detects packet bus
buffer overflow, it increments the error on the FIFO Overflow error counter. This
test reads and clears the counter.
If errors are:
Occasional
Persistent
Table 145. TEST #596 Receive FIFO Overflow Error Counter Test
Error
Test
Code
Result
2000
ABORT
Did not receive circuit pack test response within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run test.
2500
ABORT
Internal system error.
1-10
FAIL
Circuit pack detects overflow errors. The error code indicates the value of the
on-board error counter.
PASS
Circuit pack detects no errors.
886
Issue 5 October 2002
Then they may be due to:
Statistical buffer sizing
Circuit pack congestion that requires redistribution of traffic load
Description/ Recommendation
1. Retry command at 1-minute intervals, up to 5 times.
2. If the problem persists, reset the circuit pack (reset board UUCSS).
3. If the problem persists, replace the circuit pack.
1. Retry the command at 1-minute intervals, up to 5 times.
2. If the problem persists, escalate the problem.
1. Retry the command at 1-minute intervals, up to 5 times.
2. If the test continues to fail, execute the Packet Interface Test (#598) (test
board UUCSS).
3. If Packet Interface Test (#598) fails, refer to Packet Bus repair
procedures.