Avaya DEFINITY Server CSI Maintenance Manual page 830

Table of Contents

Advertisement

Maintenance Objects
Table 123. ISDN-BRI Cause Values — Continued
Code
Explanation
69
Requested
Facility Not
Implemented
Adjunct switch
error conditions
81
Invalid CRV
System Technician-Demanded Tests: Descriptions
and Error Codes
When inspecting errors in the system and deciding which ones to address, always
investigate errors associated with the circuit pack and port first. Clearing these
error codes first may also clear errors generated against the endpoint. When all
circuit pack and port errors have been cleared, and errors still exist against the
endpoint, always investigate errors in the order they are presented in the table
below. By clearing error codes associated with the Signaling Link Status Test, for
example, you may also clear errors generated from other tests in the testing
sequence.
Table 124. System Technician-Demanded Tests: BRI-SET
Order of Investigation
Signaling Link Status Test (#626)
BRI XID Test (#628)
BRI Layer 3 Query (#629)
BRI Remote Loop Back (#627)
BRI Set Audits (#630)
BRI Vendor ID Test (#631)
BRI Model/Vintage ID Test (#632)
1.
D = Destructive, ND = Non-destructive
Note:
a. Use test port long PCSSpp and look at the results of the BRI Port Local
LAN Loop Around Test to verify the repair.
830
Issue 5 October 2002
Requested service not supported in switch or endpoint.
1. Consult switch and endpoint documentation to determine service
support.
An invalid CRV was sent by the adjunct.
1. This may indicate a CRV inconsistency between the switch and
the adjunct. See the CallVisor protocol reference manual.
Short Test
Sequence
X (a)
X (a)
Recommendation
Continued on next page
Long Test
Sequence
X
X
X
X
X (a)
X (a)
X (a)
X (a)
X (a)
1
D/ND
ND
ND
ND
ND
ND
ND
ND
555-233-119

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents