Maintenance Commands

test sys-link

Use test sys-link to validate a link, and run diagnostic tests on the hardware
objects that comprises the system link. If the current or faulted options are
specified, tests are run on all hardware objects that comprise the specified link. If
current or faulted is not specified, only the end-to-end sys-link connection is
tested.
The hardware path that comprises a system link consists of up to 21 hardware
components that affect the behavior of the link. The number of components of a
given system link hardware path depends on the system configuration and type of
system link.
Action/
Object
Qualifier
test
location
sys-link
current
faulted
short
long
repeat
number
clear
schedule
1
If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence.
2
See the Report Scheduler and System Printer feature specification for more details.
592
Issue 5 October 2002
Qualifier Description
Port location associated with the system
link.
Current hardware path tested
Tests the hardware path of the system link
as it was constituted when a fault last
caused the link to go down.
Option for a brief series of nondestructive
diagnostic tests.
Option for a longer, more comprehensive
series of both destructive and
nondestructive diagnostic tests.
How many times each test in the sequence
is repeated (1-100)
This option causes the test sequence (short
or long) to repeat until the alarm (if any) is
cleared or a single test in the sequence
1
fails.
Use the screen to schedule execution of the
command. The command is placed in the
command queue and is executed at the
specified time. The information displayed by
the command is sent to the system printer
2
instead of the screen.
Examples:
test sys-link 2e0201 current schedule
test sys-link 2e0201 faulted r 10
Feature
Logins
Defaults
Interactions
init
none
inads
craft
555-233-119

Hide quick links: