Avaya DEFINITY Server CSI Maintenance Manual page 1318

Table of Contents

Advertisement

Table 319. TEST #7 Conference Circuit Test — Continued
Error
Test
Code
Result
1004
ABORT
1018
ABORT
1020
ABORT
2000
ABORT
2100
ABORT
Any
FAIL
PASS
1318
Issue 5 October 2002
Description/ Recommendation
The port has been seized by a user for a valid call. Use status station or
status trunk to determine when the port is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Maintenance is disabled on this trunk.
1. Enable maintenance by entering y in the
field on page 2 of the change trunk-group form.
The test did not run due to an already existing error on the specific port or a
more general circuit pack error.
Examine Error Log for existing errors against this port or the circuit pack and
attempt to diagnose the already existing error.
Response to the test request was not received within the allowable time
period.
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The NPE of the tested port did not conference the tones correctly. This will
cause noisy and unreliable connections.
1. Replace the circuit pack.
The port can correctly conference multiple connections. User-reported
troubles on this port should be investigated using other port tests and
examining station, trunk, or external wiring.
Maintenance Tests?
Continued on next page
555-233-119

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents