Avaya DEFINITY Server CSI Maintenance Manual page 708

Table of Contents

Advertisement

Maintenance Objects
Table 60. TEST #210 140AY Loop Around Test — Continued
Error
Test
Code
Result
1003
ABORT
1007
ABORT
1024
ABORT
2000
ABORT
2007
ABORT
2100
ABORT
ABORT
708
Issue 5 October 2002
Description/ Recommendation
The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present or some Tone
Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to the
''TTR-LEV (TTR Level)''
2. Look for TONE-PT errors in the Error Log. If present, refer to the
''TONE-PT (Tone Generator)''
3. If neither condition exists, retry the test at 1-minute intervals a
maximum of 5 times.
The Announcement circuit pack thinks that Port 1 or Port 9 is busy.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, follow the Announcement Port
maintenance procedures for Ports 1 and 9.
Announcement circuit pack blocked the test because an announcement
download is in progress. If an announcement download is in progress, a
status data-module <announcement data extension> command should
show that the announcement data port is connected to a NETCON data
channel, and the "card-in-use" LED for the memory card should be on (to
determine the extension of the announcement data module, use the list
data-module command). See Note (a) at end of table for more information.
1. Wait until download is finished (can take up to 45 minutes), and run the
test again.
2. If the test continues to abort and there is no download in progress,
escalate the problem.
Response to the test request was not received within the allowable time
period. If Error Type 1538 is present in the Error Log, follow the
maintenance strategy recommended for this error type.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The Announcement circuit pack thinks that Port 1 or Port 9 is busy.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, follow the Announcement Port
maintenance procedures for Ports 1 and 9.
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Internal system error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Maintenance documentation.
Maintenance documentation.
Continued on next page
555-233-119