Maintenance Objects
Table 47. TEST #36 Station Status and Translation Audits and Updates Test — Continued
Error
Test
Code
Result
1005
ABORT
1006
ABORT
ABORT
2000
ABORT
2100
ABORT
1
FAIL
5
FAIL
7
FAIL
666
Issue 5 October 2002
Description/ Recommendation
The test was aborted due to a configuration problem. This code will result
under either of the following conditions:
1. This test may not be applicable, or it may be disruptive to terminal
equipment other than a voice terminal (for example, the modem pool
member or music on hold).
2. The circuit pack is one of the following:
— TN742 vintages 13, 14 and 15
— TN769 vintages 3, 4 and 5
This port has been busied out by command or taken out-of-service by the
failure of the NPE Crosstalk Test.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If
this error is present, use release station extension to release the port
and run the test again.
2. Look in the Error Log for Error Type 1025 (NPE Crosstalk Test failed)
for this port. If this error is present, investigate the errors associated
with the NPE Crosstalk Test (#6) first.
3. Make sure that the terminal is connected and in service and retest.
Could not allocate the necessary system resources to run this test.
Response to the test request was not received within the allowable time
period.
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
This does not indicate a hardware problem. The switchhook audit failed,
and the other updates were not performed because of this failure. This
condition may occur when the audit is performed at the same time that the
terminal equipment goes off-hook. Use status station to determine when
the port is available for testing.
1. When the port becomes available for testing, retry the command at
1-minute intervals a maximum of 5 times.
This does not indicate a hardware problem but may indicate an internal
software error. The message waiting lamp update failed. The translation
and ringer updates were not performed because of this failure.
The translation update failed. The ringer update was not performed
because of this failure. This does not indicate a hardware problem but may
be an internal software error.
Continued on next page