Avaya DEFINITY Server CSI Maintenance Manual page 1382

Table of Contents

Advertisement

Maintenance Objects
Table 354. TEST #1371 IP Address Query Test — Continued
Error
Test
Code
Result
FAIL
PASS
Ping Test (#1379)
This test is non-destructive
This test verifies that the MedPro circuit pack can communicate to other nodes on
the LAN.
This test pings the gateway IP address as defined on the IP Interface form.
If the PING is successful, this test looks at the PING round trip delay. If a round
trip delay of greater than 4 seconds is reported, a separate error is logged.
Excessive round trip delays do not take the MedPro out of service.
Services can execute the standard PING command using the C-LAN board
address and MedPro IP address to see the actual round-trip delay. (See ping
commands).
This test is a nondestructive test. It runs because of in-line errors, during periodic
and schedule maintenance, and on demand.
1382
Issue 5 October 2002
Description/ Recommendation
The IP address, subnet mask, and gateway translation parameters
do not match DEFINITY translations. After the new values are written
into the Windows registry, the NT PC must go through a reboot. The
board goes through a physical board removal and insertion.
If the problem persists, replace the circuit pack.
Translation data matches the Windows Registry.
Continued on next page