Avaya DEFINITY Server CSI Maintenance Manual page 654

Table of Contents

Advertisement

Maintenance Objects
Table 43. TEST #161 Looparound Test — Continued
Error
Test
Code
Result
1018
ABORT
The test has been disabled via administration. The default for the
on the Station screen is y. Determine why this field has been set to
station. It may be due to application Test #48, which can disturb users or
terminal operations.
1. To enable the test for the station being tested, enter change station
2000
ABORT
Response to the test request was not received within the allowable time
period.
2100
ABORT
Could not allocate the necessary system resources to run this test. This could
be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL
The reflective loop around test failed. This could cause noisy or unreliable
connections, or users calling this port may hear an echo. The problem can also
be off-board.
1. Since the test may be affected by a line seizure, repeat the test at
2. Use test board PCSS short to run circuit pack tests to check the tone
3. Resolve any problems on the tone generator circuit pack or the tone
4. If the tone generator and tone detector circuit packs are functioning
PASS
The port is able to provide an analog transmission path to the station
equipment. User-reported troubles on this port should be investigated by using
other port tests, by examining station wiring, or by examining the station.
0
NO
The test could not relate the internal ID to the port (no board). This could be
BOARD
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use list config
2. If the board was found to be correctly inserted in step 1, use busyout
3. Issue reset board.
4. Issue release busy board.
5. Issue test board long. This should re-establish the linkage between the
654
Issue 5 October 2002
Description/Recommendation
extension and set the
Test
1-minute intervals for a maximum of 5 times.
generator circuit pack and the tone detector circuit pack.
detector circuit pack.
properly, a voice terminal is connected and wired properly and the test still
fails, replace the analog line circuit pack.
and resolve any problems.
board.
internal ID and the port. If this is not the case, check to ensure that there is
a valid board inserted.
field to y.
Continued on next page
Test
field
n
for this
555-233-119

Hide quick links:

Advertisement

Table of Contents
loading