Avaya DEFINITY Server CSI Maintenance Manual page 1058

Table of Contents

Advertisement

Hardware Error Log Entries and Test to Clear
Values
Table 214. DIOD Trunk Error Log Entries
Error
Aux
Type
Data
1
0
0
15 (b)
any
18
0
769 (a)
57392
1537
1793
2049
2561 (a,d)
57345
2817 (a,e)
57393
3073 (a,c)
57376
3073 (a,c)
57424
3585 (a,c)
57424
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2.
Minor alarms on this MO may be downgraded to warning alarms based on the values used in the
set options command. If the Minor alarm is not downgraded by the set-options values, the Minor
alarm is upgraded to a Major alarm if 75 percent of the trunks in this trunk group are alarmed.
Notes:
a. These are in-line errors that have no specific test associated with them.
Refer to the following table for an explanation and appropriate action.
b. This is a software audit error that does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate associated
errors (if any).
c. Aux data 57376 - No loop current on incoming call
Aux data 57424 - No loop current on outgoing call
1058
Issue 5 October 2002
Alarm
Associated Test
Any
Any
Port Audit Update
Test (#36)
busyout trunk
<grp>/<mbr>
None
MAJ/MIN/
WRN
Dial Tone Test
MAJ/MIN/
(#0)
WRN
Loop Around and
MAJ/MIN/
Conference Test
WRN
(#33)
NPE Cross Talk
MAJ/MIN/
Test (#6)
WRN
None
None
None
None
None
On/Off
Level
Board
Any
ON
2
ON
2
ON
2
ON
2
Test to Clear Value
test port PCSSpp sh r 1
test port PCSS l r 2
test port PCSS l r 3
test port PCSS l r 3
Continued on next page
555-233-119