Avaya DEFINITY Server CSI Maintenance Manual page 835

Table of Contents

Advertisement

BRI-SET, ASAI-ADJ, BRI-DAT
Table 126. TEST #627 BRI Remote Loop Back — Continued
Error
Test
Code
Result
1187
ABORT
2012
ABORT
2068
ABORT
2069
ABORT
2100
ABORT
555-233-119
Description/ Recommendation
The circuit pack, port or station may have been busied out by a technician.
1. Look in the Error Log for Error Type 18 (busied out) for BRI-BD,
BRI-PORT, or BRI-SET.
2. If this error type is present for BRI-SET only, release the station with
release station.
a. If this error type is present for BRI-PORT and BRI-SET, release the
port with release port PCSSpp and run the test again.
b. If the error is present for BRI-BD, BRI-PORT, and BRI-SET, release
the circuit pack with release port PCSSpp and run the test again.
If the error is present for both BRI-BD and BRI-PORT, release the
circuit pack with release board PPCSS and run the test again.
If the error is present for BRI-SET only, release the circuit pack with
release port PPCSS and run the test again.
NOTE:
When you release the circuit pack, you release all ports
associated with it. If certain ports still need to be busied
out, use the release port PCSSpp command to busy
them out.
3. Make sure the terminal is connected.
4. Retry the command at 1-minute intervals a maximum of 5 times.
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
The endpoint has rejected the switch sent application message. This
indicates that the endpoint does not support the ISDN-BRI Management
and Maintenance Procedure for Loop Back Testing.
1. Use change station extension and set the
to n.
The endpoint has returned an error response to the application message
sent by the switch.
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
MIMs Supported
Continued on next page
Issue 5 October 2002