Avaya DEFINITY Server CSI Maintenance Manual page 564

Table of Contents

Advertisement

Maintenance Commands
Output
The following example shows the output for test isdn-testcall 77/1. The
responses appear on a test-by-test basis with one line of data for each test result.
test isdn-testcall 77/1
Port
Maintenance Name
01B1501
ISDN-TRK
Field descriptions
Port
Maintenance
Name
Alt. Name
Test No
Result
Error Code
564
Issue 5 October 2002
TEST RESULTS
Alt. Name Test No. Result
077/001
Port address: cabinet-carrier-slot-circuit
The name of the maintenance object being tested.
Alternate means of identifying the maintenance object: trunk
object xxx/yyy, where xxx = trunk group number, yyy =
member number
The test being executed
Test result: Pass, Abort, Fail, No Board, Disabled, or Extra Bd.
Numeric code explaining why the release failed or aborted. See
the detailed list of the codes by test number for each MO.
SPE A
258
PASS
Error Code
555-233-119