Avaya DEFINITY Server CSI Maintenance Manual page 1113

Table of Contents

Advertisement

DS1-BD (DS1 Interface Circuit Pack)
Table 234. TEST #145 Misframe Alarm Inquiry Test — Continued
Error
Code
Test Result
2000
ABORT
555-233-119
Description/ Recommendation
Response to the test was not received within the allowable time period.
This may be due to hyperactivity. Error type 1538 in the error log indicates
hyperactivity. The hyperactive circuit pack is out of service and one or
more of the following symptoms may appear.
1. The DS1-BD tests (such as test 138 and test 139) are aborting with
error code 2000.
2. The tests run on the ports of this circuit pack are returning a no board
result.
3. A busyout or a release command has no affect on the test results.
4. A list config command shows that the circuit pack and the ports are
properly installed.
NOTE:
When hyperactivity occurs, the circuit pack is isolated from the
system, and all of the trunks for this circuit pack are placed into the
out of service state. The system will try to restore the circuit pack
within 15 minutes. When no faults are detected for 15 minutes, the
DS1 interface circuit pack is restored to normal operation. All of the
trunks for the DS1 interface circuit pack are then returned to the in
service state. Hyperactivity is often caused by the associated facility.
In such a case, faults (such as slips, misframes, or blue alarms)
would be entered in the error log. In addition, many hardware errors
would be logged against the associated trunk circuits. If the facility is
OK and the error occurs again after 15 minutes, escalate this
problem.
Continued on next page
Issue 5 October 2002
1113

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents