Avaya DEFINITY Server CSI Maintenance Manual page 630

Table of Contents

Advertisement

Maintenance Objects
Table 33. TEST #13 Voice and Control Channel Local Loop Test — Continued
Error
Test
Code
Result
7
FAIL
14
FAIL
15
FAIL
16
FAIL
None
FAIL
PASS
630
Issue 5 October 2002
Description/Recommendation
Conference Test failed on the primary channel. In some cases, users may
not notice a disruption in service. In extreme cases, the conferencing
feature may not work at all.
The primary voice channel is not transmitting properly. User impact may
range from no noticeable effect to loss of use of this port.
The control channel between the processor and AUDIX is not transmitting
properly. User impact may range from no noticeable effect to loss of use of
this port. This failure could also be disruptive to other users.
The secondary voice channel is not transmitting properly. User impact may
range from no noticeable effect to loss of use of this port.
The test failed for reasons external to the AUDIX.
1. Use test board PCSS to run circuit pack tests to check the tone
generator circuit pack and the tone detector circuit pack.
2. Resolve any problems detected on the tone generator circuit pack or
tone detector circuit pack.
3. If the tone generator and tone detector circuit packs are functioning
properly, and if the test still fails, replace the AUDIX (see caution at the
beginning of this section).
Voice and Control Channel Local Loop test passed. All channels are
transmitting properly.
1. To be sure that this is not an intermittent problem, repeat this test up to
10 times and see if it continues to pass.
2. If complaints still exist, examine the connections.
Continued on next page
555-233-119

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents