Avaya DEFINITY Server CSI Maintenance Manual page 560

Table of Contents

Advertisement

Maintenance Commands
Once the call is answered by INADS, the system sends a message with a test
alarm type. INADS acknowledges receipt of the message and creates a trouble
ticket. The trouble ticket is closed immediately and has a "INADS LINK TEST"
message entered in the description field. If an alarm is raised while the test call is
up, the system does not send an alarm message over the existing link. The
normal retry mechanism is followed, which means an attempt to make a call to
INADS to report the error takes place 7 minutes later. An INADS trouble ticket is
created only if the connection is successfully established and a message is sent
to the system acknowledging that INADS received the system message.
The Maintain Process Circuit Packs field must be set to yes on the inads
and technician permission forms. This will provide permissions to execute test
inads-link. Use change permission login to change the field.
No alarms are raised on the system and attendant alarm and acknowledgment
lamp states are not changed as a result of test inads-link. The test does not run
during periodic or scheduled maintenance.
Action/Object
Qualifier
test inads-link
1
2
Output
Command successfully
completed
Command failed
560
Issue 5 October 2002
Qualifier Description
First OSS telephone number
Second OSS telephone number
Examples:
test inads-link
test inads-link 1
test inads-link 2
Test passed
Link was up, there was an active alarm that the switch needs to
report, or there was a problem with the call.
An entry is made in the error log describing why the inads-link
test failed.
Logins
Defaults
Feature Interactions
init
1st OSS
none
inads
number
craft
nms
555-233-119