Bri-Set, Asai-Adj, Bri-Dat - Avaya DEFINITY Server CSI Maintenance Manual

Table of Contents

Advertisement

BRI-SET, ASAI-ADJ, BRI-DAT

BRI-SET, ASAI-ADJ, BRI-DAT
MO Name (in
Alarm Log)
Alarm Level
BRI-SET
WARNING
ASAI-ADJ
MAJOR
ASAI-ADJ
MAJOR
ASAI-ADJ
WARNING
ATT-ADJ
MAJOR
ATT-ADJ
MAJOR
ATT-ADJ
WARNING
LGATE-AJ
MAJOR
LGATE-AJ
MAJOR
LGATE-AJ
WARNING
ATTE-AJ
MAJOR
ATTE-AJ
MAJOR
ATTE-AJ
WARNING
BRI-DAT
1.
Where P is the port network number (1 for PPN); C is the carrier designation (A, B, or C); SS is
the address of the slot in the carrier where the circuit pack is located (01, 02, etc.); and pp is the
2-digit port number (for example, 01). The alternate name field contains the extension of the
endpoint. This field is used to distinguish between endpoints on the same port.
2.
The alarm level for ASAI and adjuncts may be administered using the set options command. The
alarm level can be set independently for Off-Board and On-Board alarms to WARNING, MINOR,
or MAJOR for all ASAI and adjuncts in the system.
3.
Alarming for an ASAI and adjuncts is disabled if the adjunct asks the switch to suspend
maintenance. When this occurs, an error and a WARNING alarm are logged against the endpoint.
Busying out and releasing the ASAI station or ADJLK station will clear the alarm.
The TN2208 ESAI MFB provides the Avaya Definity Server CSI with an Ethernet
interface to Adjunct-Switch Application Interface (ASAI) and adjuncts (for
example, CONVERSANT ® Voice System). This circuit pack contains 8 ports of
line circuit interface, each of which operates with two B-channels (referred to as
B1 and B2 throughout this section) and one D-channel as specified in the
ISDN-BRI Specification. In this context, the term ' ' ISDN-BRI port'' is used to refer
collectively to ports on the TN2208 MFB circuit pack which is connected to ASAI
or adjuncts. The TN2208 ESAI MFB is handled by switch software as it is an ISDN
BRI compatible board and all maintenance actions referring to ASAI and Adjunct
Links in this section apply.
555-233-119
Initial Command to Run
2
test station extension l,
test data-module extension
2
test station extension
2
test data-module extension
3
test data-module extension
2
test station extension
2
test station extension
3
test station extension
2
test station extension
2
test station extension
3
test station extension
2
test station extension
2
test station extension
3
test station extension
test data-module
1
Full Name of MO
ISDN-BRI Set
ASAI-Adjunct
ASAI-Adjunct
ASAI-Adjunct
-Adjunct
-Adjunct
-Adjunct
Ethernet ASAI-Adjunct
Ethernet ASAI-Adjunct
Ethernet ASAI-Adjunct
Ethernet -Adjunct
Ethernet -Adjunct
Ethernet -Adjunct
Issue 5 October 2002
819