ATM-INTF (TN2305/6)
LED states
The ATM-INTF circuit pack has the standard red, green and yellow LEDs. The red
and green LEDs have the traditional use: red indicates an alarm condition, green
means maintenance testing in progress. The yellow LED is not used. The possible
LED states are listed below:
LED
Condition
Red
Board is not healthy
Red
Board is in the processes of booting
Green
Green
Maintenance is running tests on the board
Yellow
Fiber LOS
Yellow
Signal to the ATM switch is down
Error Log Entries and Test to Clear Values
Error
Aux
Type
Data
Associated Test
23(a)
0
None
125(b)
None
217(c)
0
None
Notes:
a. Error Type 23: ATM Expansion Interface circuit pack is administered with
change circuit-pack, but has not been inserted into the system. Insert the
circuit pack.
b. Error Type 125: A wrong circuit pack is located in the slot where this circuit
pack is logically administered. To resolve this problem, either remove the
wrong circuit pack or insert the logically administered circuit pack.
c. Error Type 217: The ATM circuit pack is physically present but has not
been given a personality. Remove the circuit pack or administer it using the
add atm pnc command or add atm trunk command.
555-233-119
LED
Solid on, never off
Red: solid on
Green: 200 ms on 200 ms off
Solid on,
off when maintenance completed
100 ms on, 100ms off
500 ms on, 500 ms off
Alarm
On/Off
Level
Board
WAR
OFF
MIN
ON
WAR
OFF
Test to Clear Value
Issue 5 October 2002