CARD-MEM (Memory Card)
Table 137. TEST #694 Memory Card Translation Data Integrity Test — Continued
Error
Test
Code
Result
2111
ABORT
2112
ABORT
Any
FAIL
PASS
555-233-119
Description/ Recommendation
Inserted memory card cannot be recognized.
1. Insert a new formatted memory card into the slot at the Processor
circuit pack.
2. Retry the command at 1-minute intervals a maximum of 5 times.
Internal system error The inserted memory card is a system-upgrade
memory card.
1. Replace the inserted memory card with a user's memory card.
2. Retry the command at 1-minute intervals a maximum of 5 times.
A checksum error is detected in the translation file that is stored in the
inserted memory card.
1. Use save translation to verify that translations can be successfully
saved onto the memory card.
2. Rerun the test.
3. If the test fails again, replace the memory card, and repeat Steps 1 and
2.
No checksum error is found in the translation file.