H323-SGRP (323 Signaling Group)
i. Error Type 2305 — indicates that the Gateway (signaling group on the
Remote Office) is unregistered. Because the signaling group is still known,
the error against MO H323-SGRP generates a Minor alarm when this
failure occurs. This error is only applicable if the change signaling group
form has the RRQ field set to y.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. By clearing error codes associated with the
Status Test (#1386)
tests in the testing sequence.
Order of Investigation
CLAN Ethernet Status Test (#1386)
MedPro Status Test (#1392)
H.323 Signaling Group Ping Test (#1387)
1.
D = Destructive; ND = Nondestructive
CLAN Ethernet Status Test (#1386)
This test is non-destructive.
This test checks the status of the CLAN ethernet port that originated this signaling
group. If the CLAN ethernet port is in-service, the test passes; if it is out of service
(OOS), the test fails.
NOTE:
Failure of this test will put the SIG-GRP in the OOS state.
555-233-119
, for example, you may also clear errors generated from other
CLAN Ethernet
Short Test
Long Test
Sequence
Sequence
X
X
X
X
X
X
Issue 5 October 2002
1
D/ND
ND
ND
ND