TCP/IP PING Test (#1281)
This non-destructive test fails if all the endpoints fail to respond. Use this test to
check the circuitry in the data path for a peer-to-peer IP layer connection.
Table 258. TEST #1281 TCP/IP PING Test
Error
Test
Code
Result
1, 2,
ABORT
Internal error
11
7
ABORT
Destination unreachable.
1005
ABORT
Incorrect test configuration.
1124
ABORT
Ethernet link is not enabled.
1125
ABORT
Ethernet link not in service.
555-233-119
Description/ Recommendation
1. Retry the command at 1-minute intervals a maximum of 3 times.
2. If the problem persists, escalate the problem.
1. Verify that there is a destination to ping in the routing table (list ip-route
and look for destinations reachable through this ethernet port).
2. If there are no reachable destinations from this port (i.e., no routes
administered on ethernet), administer a route and retry.
3. Escalate if the problem persists.
1. Verify Ethernet link is in service (status port UUCSSpp or status link
n).
2. Verify that Ethernet link is enabled (status port UUCSSpp or status
link n or display data-module).
3. Verify routing table has reachable destinations.
4. Repeat the test.
5. If problem persists while the Ethernet link is in service and enabled,
escalate the problem.
1. Verify that the Ethernet link is enabled (status port UUCSSpp, status
link n, or display data-module).
2. If the link is not enabled, enable the link (change data-module).
3. Repeat the test.
4. Escalate if the problem persists.
1. Verify Ethernet link is in service (status port UUCSSpp or status link
n).
2. If the link is not in service, release the link using (release link n or
release port UUCSSpp).
3. Repeat the test.
4. Escalate if the problem persists.