Avaya DEFINITY Server CSI Maintenance Manual page 978

Table of Contents

Advertisement

Error Log Entries and Test to Clear Value
Table 179. Data Line Error Log Entries
Error
Aux
Type
Data
1
0
0
1
15(a)
Any
18
0
130(b)
257
513
769(a)
Any(c)
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Notes:
a. This is a software audit error that does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate errors (if any).
b. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
c. This error is logged when the Data Line circuit pack finds an error with the
transmit/receive circuitry of an administered Data Line on circuit pack
insertion. Perform the following procedure:
1. Issue the busyout board PCSS command to busyout the Data Line
2. Issue the reset board PCSS command. Check the Hardware Error
3. Issue the release board PCSS command to release the Data Line
978
Issue 5 October 2002
Associated Test
Any
Digital Loop Around
Test (#171)
Audit Update Test
(#36)
busyout port PCSSpp
None
Conference Circuit
Test (#7)
NPE Crosstalk Test
(#6)
None
circuit pack on which this port resides.
Log to determine if Error Type 769 is logged again for the DAT-LINE
MO.
NOTE:
When displaying errors, set the Active Alarms Only field
to n.
If Error Type 769 reappears, replace the DAT-LINE circuit pack. If
Error Type 769 does not reappear, proceed to Step 3.
circuit pack on which this port resides.
Alarm
On/Off
Level
Board
Any
Any
MINOR
ON
WARNING
OFF
WARNING
ON
MINOR
ON
MINOR
ON
Test to Clear Value
test port PCSSpp sh r 1
test port PCSSpp sh r 2
release port PCSSpp
test port PCSSpp sh
test port PCSSpp l r 2
test port PCSSpp l r 2
555-233-119

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents