Avaya DEFINITY Server CSI Maintenance Manual page 773

Table of Contents

Advertisement

ATM-TRK (Circuit Emulation Service Circuit Pack)
Control Channel Loop Test (#52)
The nondestructive Control Channel Loop Test is part of the maintenance
subsystem's Common Port Board Testing feature. The Common Port Board test
sends board vintage queries to a port circuit pack and checks the responses.
CCMS downlink notifications tell the circuit pack which TDM Bus (A or B) carries
the control channel and which carries the touch tones.
The test passes if the port circuit pack responds. The test aborts if the circuit pack
does not respond. The test fails otherwise.
Table 97.
Control Channel Test #52
Error
Test
Code
Result
2000
ABORT
Test request timed out.
2100
ABORT
Could not allocate needed system resources.
2500
ABORT
Internal system error
Retry the command up to 3 times at 1-minute intervals.
FAIL
The ATM circuit pack responded incorrectly.
Retry the command up to 3 times at 1-minute intervals.
If the test continues to fail, reset the ATM-TRK circuit pack (reset board
UUCSS).
If test continues to fail, replace the circuit pack or transceiver.
PASS
The ATM-TRK circuit pack is communicating correctly with the software.
0
NO
Circuit pack not detected.
BOARD
Check the error log for Error 125 (wrong board) or Error 131 (no board), and
correct any errors found.
Make sure that the ATM-TRK circuit pack is properly translated and inserted.
Check for Error 1538 (hyperactivity). If hyperactive, run reset board UUCSS.
Run the test again. If it fails, replace the ATM-TRK circuit pack, and retest.
555-233-119
Description/Recommendation
Issue 5 October 2002
Continued on next page
773