MAPD-BD (MAPD Interface Circuit Pack TN802)
SAKI Sanity Test (#53)
This test is destructive.
This test resets the circuit pack. The test is highly destructive and can only be
initiated by a system technician-demanded reset board UUCSS command.
Table 340. TEST #53 SAKI Sanity Test
Error
Test
Code
Result
None
ABORT
System resources required for this test are not available.
1015
ABORT
Port is not out-of-service.
2100
ABORT
System resources required for this test are not available.
1
FAIL
The circuit pack failed to reset.
2
FAIL
The circuit pack failed to restart.
PASS
The circuit pack initializes correctly.
555-233-119
Description/ Recommendation
1. Retry the reset board command at 1-minute intervals a maximum of 5
times.
1. Busyout the circuit pack (busyout board UUCSS).
2. Execute the reset board command again.
1. Retry the reset board command at 1-minute intervals a maximum of 5
times.
1. Execute the reset board command again.
2. If the problem persists, replace the circuit pack.
1. Run the Short Test Sequence.
Continued on next page