Maintenance Objects
Table 51. TEST #7 Conference Circuit Test — Continued
Error
Test
Code
Result
2000
ABORT
2100
ABORT
Any
FAIL
PASS
0
NO
BOARD
682
Issue 5 October 2002
Description/Recommendation
Response to the test request was not received within the allowable time
period.
System resources required to run this test are not available.
1. Resolve any TONE-PT errors in the error log.
2. If there are no TONE-PT errors, retry the command at 1-minute
intervals no more than 5 times.
3. If the test continues to abort, escalate the problem.
The NPE of the tested port did not conference the tones correctly. This
causes noisy and unreliable connections.
1. Use display port UUCSSpp and status station extension to
determine if the station is idle.
2. If the station is idle, use test port UUCSSpp for this port.
3. If the test continues to fail, use busy port UUCSSpp and release port
UUCSSpp, and retest.
4. If the test still fails, replace the board.
The port can correctly conference multiple connections. Investigate
user-reported troubles on this port by running other port tests; by
examining station, trunk, or external wiring; or by inspecting the station.
The test could not relate the internal ID to the port (no board). This result
could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Check to make sure that the board translations are correct. Use list
configuration and resolve any problems.
2. If the board is correctly inserted, use busy board UUCSS.
3. Issue reset board UUCSS.
4. Issue release board UUCSS.
5. Issue test board UUCSS long. This re-establishes the link between
the internal ID and the port.
6. If this is not the case, check to make sure that a valid board is inserted.
Continued on next page
555-233-119