Avaya DEFINITY Server CSI Maintenance Manual page 1366

Table of Contents

Advertisement

Maintenance Objects
Control Channel Looparound Test (#52)
This test queries the circuit pack for its circuit pack code and vintage and verifies
its records.
Table 339. TEST #52 Control Channel Looparound Test
Error
Test
Code
Result
None
ABORT
System resources required for this test are not available.
2100
FAIL
The circuit pack failed to return the circuit pack code or vintage.
PASS
Communication with this circuit pack is successful.
0
NO
The test could not relate the internal ID to the port (no board). This could be
BOARD
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
This should re-establish the linkage between the internal ID and the port.
1366
Issue 5 October 2002
Description/ Recommendation
1. Retry the command at 1-minute intervals a maximum of 5 times.
1. Retry the command a maximum of 5 times.
2. If the problem continues, and if the circuit pack is one of the Port circuit
packs, replace the circuit pack.
3. Otherwise, if the circuit pack is part of the SPE, use the procedure
described in Replacing SPE Circuit Packs in Chapter 5.
1. Ensure that the board translations are correct. Execute the add ds1
UUCSS command to administer the MAPD interface if it is not already
administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the board
is shut down. Reseating the board re-initializes the board.
3. If the board was found to be correctly inserted in step 1, then issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
Continued on next page