DIOD-TRK (DIOD Trunk)
Table 217. TEST #6 NPE Crosstalk Test — Continued
Error
Test
Code
Result
1004
ABORT
2000
ABORT
2100
ABORT
Any
FAIL
PASS
555-233-119
Description/ Recommendation
The port was seized by a valid call during the test. The test has been
aborted. Use the display port PCSSpp command to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. You must wait
until the port is idle before retesting.
Response to the test request was not received within the allowable time
period.
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The NPE of the tested port was found to be transmitting in error. This
causes noisy and unreliable connections.
1. Replace the circuit pack.
The port is correctly using its allocated time slots. User-reported troubles on
this port should be investigated by using other port tests and by examining
trunk or external wiring.
Continued on next page