Avaya DEFINITY Server CSI Maintenance Manual page 938

Table of Contents

Advertisement

Maintenance Objects
Table 166. TEST #844-848 Transmission Test — Continued
Error
Test
Code
Result
1938
ABORT
1939
ABORT
1940
ABORT
1941
ABORT
1942
ABORT
1943
ABORT
1944
ABORT
1945
ABORT
1946
ABORT
1947
ABORT
2000
ABORT
2012
ABORT
2053
ABORT
938
Issue 5 October 2002
Description/ Recommendation
Near-end self test failed.
1. Test the TN2402/TN798 circuit pack.
Loss self check at 0dBm at 1004 Hz failed.
1. Test the TN2402/TN798 circuit packs.
2. If the test continues to abort escalate the problem.
Far end noise self check failed.
1. The problem is with the far end system; a technician at the far end
should test the test line.
High frequency singing return loss self check failed.
1. Test the TN2402/TN798 circuit packs.
Echo return loss self check failed.
1. Test the TN2402/TN798 circuit packs.
Singing return loss self check failed.
1. Test the TN2402/TN798 circuit packs.
Loss self check at -16 dBm at 1004 Hz failed.
1. Test the TN2402/TN798 circuit packs
Loss self check at -16 dBm at 404 Hz failed.
1. Test the TN2402/TN798 circuit packs.
Loss self check at -16 dBm at 2804 Hz failed.
1. Test the TN2402/TN798 circuit packs.
Noise with tone self check failed.
1. Test the TN2402/TN798 circuit packs.
The test timed out while waiting for a response from the TN2402/TN798
circuit pack.
1. Retry the command at 1-minute intervals a maximum of 5 times.
An internal software error occurred.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The test call could not be established, but no information on why is
available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
555-233-119

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents