Avaya DEFINITY Server CSI Maintenance Manual page 1047

Table of Contents

Advertisement

DIOD-DS1 (DS1 DIOD Trunk)
Hardware Error Log Entries and Test to Clear
Values
Table 209. DS1 DIOD Error Log Entries
Error
Aux
Type
Data
1
0
0
Any
1(a)
57408
1(a)
57487
57476
57477
57485
15(b)
Any
Port Audit and Update
Test (#36)
18(c)
0
busyout trunk
<grp>/<mbr>
130(d)
None
257(e)
57392 DS1 CO Dial Tone
Seizure Test (#314)
513(f)
57393 DS1 Tie Trunk Seizure
Test (#136)
769(g)
57484
1025(h)
51200
1025
DS1 CO Dial Tone
Seizure Test (#314)
1281
Conference Circuit Test
(#7)
1537
NPE Crosstalk Test (#6) MIN/WRN
1793(i)
2049(j)
57473
57474
57475
2305(k)
50944
2562(l)
16665
2817(m)
52992
3840(n)
Port Audit and Update
Test (#36)
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2.
This alarm will only be raised when the System-Parameter Country form has the Base Tone
Generator field set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this
trunk group are out of service, then the alarm will be upgraded to a MAJOR alarm.
3.
Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
555-233-119
Associated Test
Any
WARNING
WARNING
MIN/MAJ
MIN/MAJ
MIN/
WRN
MIN/
WRN
Alarm
On/Off
Level
Board
Any
test trunk <grp>/<mbr>
OFF
release trunk <grp>/<mbr>
ON
test trunk <grp>/<mbr>
2
OFF
2
OFF
OFF
test trunk <grp>/<mbr> r 2
3
ON
test trunk <grp>/<mbr> l r 4
3
3
ON
test trunk <grp>/<mbr> l r 3
test board PCSS l
Issue 5 October 2002
Test to Clear Value
Continued on next page
1047

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents