Maintenance Commands
Emergency Transfer Switch position on the Processor(s) or the
SELECT SWITCH
EPN maintenance circuit pack and the state of Emergency Transfer
in the cabinet display:
The Expansion Link does not exist in the system; a dash (-)
EXP-LINK
displays.
blank = Expansion Interface Link does not exist
SERVICE STATE
blank = Expansion Interface Link does not exist
MODE
CMC (Compact Modular Cabinet)
CABINET TYPE
SPE Modes
Simplex SPE Modes
active
blank
Busyout Modes
busyout/idle
busyout/entering
busyout/testing
516
Issue 5 October 2002
on: Designated analog phones in this cabinet are cut through to
CO trunk lines only in an emergency situation.
off: Emergency Transfer is off and cannot be invoked. The
switch should only be in this state when a service technician is
on site.
auto-on: The switch is in the or auto position, however,
because of a serious system fault, system software has
invoked Emergency Transfer.
auto-off: Switch in the auto position; because system has no
serious faults, system software has not invoked Emergency
Transfer
blank = If the system is Simplex, then the 1B Emergency
Transfer indication for the PPN will display a blank. If the
system does not have an EPN, then both the 1A and 1B
Emergency Transfer indications for the EPN will display a
blank.
1A SPE in a simplex system is always the active SPE
No 1B SPE in a simplex system
SPE busied out and there is no current maintenance activity.
The active SPE can be active or selected.
SPE busied out and is in the process of restarting the switch
software on this SPE. After the switch software finishes its
initialization, the standby SPE is available for maintenance
functions on the standby SPE.
SPE busied out, and the switch software on this SPE has been
restarted and is in the process of executing a test command.