Avaya DEFINITY Server CSI Maintenance Manual page 772

Table of Contents

Advertisement

Maintenance Objects
Table 96. TEST #50 Connection Audit Test
Error
Test
Code
Result
None
ABORT
System resources required for this test are not available.
2100
Retry the command up to 5 times at 1-minute intervals.
1019
ABORT
The test aborted because a test was already running on the port.
Retry the command up to 5 times at 1-minute intervals.
FAIL
Internal system error
Retry the command up to 5 times at 1-minute intervals.
PASS
The circuit pack has been updated with its translation.
0
NO
The test could not relate the internal ID to the port (no board). This could be
BOARD
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
Check the board translations.
If the ATM-TRK circuit pack is not administered, run add atm trunk UUCSS.
If the ATM-TRK circuit pack is administered correctly, check the error log.
If ATM-TRK circuit pack is hyperactive, shut down, and reseat the circuit pack
to force re-initialization.
If the ATM-TRK circuit pack is correctly inserted, run busyout board.
Run reset board.
Run release busy board.
Run test board long to re-establish the linkage between the internal ID and
the port.
772
Issue 5 October 2002
Description/Recommendation
Continued on next page
555-233-119

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents