test ds1-loop

Output
The following example shows the output from test data-module 300. The
responses appear on a test-by-test basis with one line of data for each test result.
test data-module 300
Port
Maintenance Name
01C1103
PDMODULE
Field Definitions
Port
Maintenance
Name
Alt. Name
Test No
Result
Error Code
test ds1-loop
Use test ds1-loop to validate that the board exists at the specified location, and
that the board is a TN464F or TN767E or later suffix DS1 Interface board.
Long-duration loopback tests execute for an extended period of time until
manually terminated. Short-duration loopback tests return the result of the test to
the screen after executing.
Use list measurements ds1 summary to monitor the status of a long-duration
loopback/span test.
555-233-119
TEST RESULTS
Alt. Name Test No. Result
Port address (cabinet-carrier-slot-circuit)
The name of maintenance object
Alternate way to identify maintenance objects.
If the Object is The field contains
station
extension
trunk
xxx/yyy (xxx=trunk group, and yyy=number)
private CO line P/xxx (xxx = private CO line group number)
The test being executed
Test result: Pass, Fail, Abort, No Board
Numeric code explaining why the release failed or aborted. See the
detailed list of the codes by test number for each MO.
Error Code
17
PASS