Avaya DEFINITY Server CSI Maintenance Manual page 800

Table of Contents

Advertisement

Maintenance Objects
Table 109. ISDN-BRI Port Error Log Entries — Continued
Error
Aux
Associated
Type
Data
Test
769 (e)
0
none
1281(f)
NPE Crosstalk
(#617)
1537(g)
46210
CRC Error
Counter (#623)
1793(h)
BRI Port Local
TDM
Loop Around
(#619)
3841(i)
46208
None
3842(j)
0
None
3843(k)
0
None
3844(l)
46223
None
3845(m)
None
3846(n)
TEI
None
3847(o)
0
None
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description, and follow the recommended procedures.
2.
Major and Minor alarms on this MO may be downgraded to Warning alarms based on the value
used in the set options command.
Notes:
a. This error occurs when the Level 1 Status Inquiry fails or when the BRI
circuit pack detects that Level 1 has been deactivated on the port. The aux
data field contains one of the following values:
Refer to the repair procedures for Test #621.
800
Issue 5 October 2002
Alarm
Level
BRI-PORT
WRN
MIN/
2
WRN
WRN
MIN/
2
WRN
blank - this indicates that the Level 1 Status Inquiry failed.
32773 - this is a message from the BRI-LINE circuit pack indicating
Level 1 has been deactivated.
Alarm Level
ABRI-PORT
ATT-PORT
On/
LGATE-POR
Off
T ATTE-PT
Board
MAJ
OFF
ON
MAJ/MIN/
OFF
2
WRN
ON
Continued on next page
Test to Clear
Value
test port
PCSSpp l r 2
test port
PCSSpp l r 2
555-233-119