Avaya DEFINITY Server CSI Maintenance Manual page 1365

Table of Contents

Advertisement

MAPD-BD (MAPD Interface Circuit Pack TN802)
NPE Connection Audit Test (#50)
The system sends a message to the on-board microprocessor to update the
network connectivity translation for the SCOTCH-NPE chip on the circuit pack.
Table 338. TEST #50 NPE Connection Audit Test
Error
Test
Code
Result
None
ABORT
System resources required for this test are not available.
2100
1019
ABORT
The test aborted because a test was already running on the port.
FAIL
Internal system error
PASS
The circuit pack's SCOTCH-NPE chip has been updated with its translation.
0
NO
The test could not relate the internal ID to the port (no board). This could be
BOARD
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
This should re-establish the linkage between the internal ID and the port.
555-233-119
Description/ Recommendation
1. Retry the command at 1-minute intervals a maximum of 5 times.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1. Ensure that the board translations are correct. Execute the add ds1
UUCSS command to administer the MAPD interface if it is not already
administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the board
is shut down. Reseating the board re-initializes the board.
3. If the board was found to be correctly inserted in Step 1, then issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
Continued on next page
Issue 5 October 2002
1365