Avaya DEFINITY Server CSI Maintenance Manual page 966

Table of Contents

Advertisement

Table 176. TEST #110 Data Channel Crosstalk Test
Error
Test
Code
Result
4
ABORT
For this test, an Error Code of 4 can have one of two different meanings:
Determine if the target DATA-CHL is in use for some other function (that is,
CDR Link, System Printer Link, Journal Printer Link, PMS Link, or secondary
administration terminal connection) as described previously in the
Data Channels''
the DATA-CHL. If there are no errors, there is a high probability that the
DATA-CHL is not defective.
Proceed with the remaining steps only if it is necessary to completely test
the target DATA-CHL:
40
ABORT
Internal system error
70
75
966
Issue 5 October 2002
Description/Recommendation
a. The target DATA-CHL is busy and, therefore, not available for use.
b. Internal system error
section. If so, check for errors on the function that is using
1. If the target DATA-CHL is in use for some other function, busyout the
function (CDR Link, System Printer Link, Journal Printer Link, PMS Link)
or the DATA-CHL (secondary administration terminal connection only).
2. Retry the command at 1-minute intervals a maximum of 5 times.
3. Restore any busied out CDR, System Printer, Journal Printer, or PMS
Link to service before moving on to another activity.
1. Retry the command at 1-minute intervals a maximum of 5 times.
''Status of
Continued on next page
555-233-119

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents