Avaya DEFINITY Server CSI Maintenance Manual page 922

Table of Contents

Advertisement

Maintenance Objects
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order they are presented in the table below when
inspecting errors in the system. By clearing error codes associated with the NPE
Crosstalk Test, for example, you may also clear errors generated from other tests
in the testing sequence.
For example, you may also clear errors generated from other tests in the testing
sequence.
Order of Investigation
NPE Crosstalk Test (#6)
Dial Tone Test (#0)
CO Demand Diagnostic Test (#3) (a)
Loop Around and Conference Test (#33)
Audit Update Test (#36)
Analog Transmission Test (#844-848) (b)
1.
D = Destructive; ND = Nondestructive
Notes:
a. A demand test of Diagnostic Test (#3) always returns a PASS indication for
CO-TRK/CO-BD [TN747B] version 8 or greater. However, any errors
produced as a result of this test are logged and produce no alarms.
If errors logged by Test #3 are the only complaints against this trunk, the
system technician should check if MFT/Range Extenders are being used. If
extenders are present, there may be excessive loop current, which causes
Test #3 to log errors.
However, all else being normal, these errors should not affect the
customer.
b. Refer to TIE-TRK (Tie Trunk) Maintenance documentation for a description
of this test.
c. ATMS test are not part of either sequence. They are run either on demand
with the test analog-testcall command or with ATMS schedule.
Dial Tone Test (#0)
This test attempts to seize a port and checks for the return of a dial tone.
922
Issue 5 October 2002
Short Test
Long Test
Sequence
Sequence
X
X
X
X
X
X
X
(c)
(c)
1
D/ND
ND
ND
ND
ND
ND
555-233-119