Test Signaling-Group - Avaya DEFINITY Server CSI Maintenance Manual

Table of Contents

Advertisement

Maintenance Commands

test signaling-group

Use test signaling-group to validate that the signaling group is administered,
and to run a series of diagnostic tests that return results and possible error codes.
A signaling group is a collection of B-channels signaled for by a designated single
D-channel or set of D-channels over an ISDN-PRI.
Action/Object
Qualifier
test
group
signaling-group
identifier
short
long
repeat
number
clear
schedule
1
If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence. SEE WARNING BELOW.
2
See the Report Scheduler and System Printer feature specification for more details.
!
WARNING:
Since the "clear long" options clear all counters if tests pass, it is possible for
firmware counters to be cleared even when a problem exists. In some cases
customer service might degrade since calls may be routed over defective
equipment.
584
Issue 5 October 2002
Qualifier Description
The station extension (must
conform to dial-plan)
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestructive
diagnostic tests.
How many times each test in the
sequence is repeated (1-100)
This option causes the test
sequence (short or long) to repeat
until the alarm (if any) is cleared or
a single test in the sequence fails.
Use the screen to schedule
execution of the command. The
command is placed in the
command queue and is executed
at the specified time. The
information displayed by the
command is sent to the system
printer instead of the screen.
Examples:
test signaling-group 1
test signaling-group 1 repeat 10
test signaling-group 2 short
test signaling-group 4 long
test signaling-group 4 long clear
test signaling-group 2 schedule
Logins
Defaults
init
Test
inads
Sequence
craft
= short;
Repeat =
1
1
2
Feature
Interactions
See below
555-233-119

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents