Avaya DEFINITY Server CSI Maintenance Manual page 736

Table of Contents

Advertisement

Maintenance Objects
Call State Audit Test (#257)
This test audits the internal call state by asking the far-end switch for the ISDN call
state. The test is particularly useful when you are trying to clear a hung call. If the
internal call state on the near-end differs from that on the far-end, the call is torn
down.
The ISDN specification allows up to 2 minutes for a reply. If a reply is not received
within the 2 minute window, the test logs a protocol time-out violation against the
associated signaling channel (ATM-DCH, Error Type 1).
NOTE:
PASS simply means that an appropriate message was composed and sent
to the far-end switch.
Table 74. TEST #257 Call State Audit Test
Error
Test
Code
Result
1018
ABORT
Maintenance disabled
1019
ABORT
Audit already in progress
1113
ABORT
Signaling link failed
1114
ABORT
Signaling link in transitional state
1116
ABORT
Trunk out-of-service
2100
ABORT
Could not allocate needed resources
FAIL
Internal system error
PASS
736
Issue 5 October 2002
Description/Recommendation
1. Enable maintenance by entering y in the Maintenance Tests field on
page 2 of the change trunk-group form.
1. Wait 2 minutes, and try again.
1. Check the results of Test #255 (Signaling Link State Check).
1. Retry the command up to 5 times at 1-minute intervals.
1. Check the trunk service state (status trunk grp#/mbr#).
1. Retry the command up to 5 times at 1-minute intervals.
1. Retry the command up to 5 times at 1-minute intervals.
1. Wait 4 minutes, and check the Error Log for call-state mismatches. If a call
state mismatch is found, the call is torn down.
Continued on next page
555-233-119

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents