Maintenance Objects
1. Run test board UUCSS long .
s. Error Type 3841: the ATM-TRK circuit pack received an unrecognized
message from the switch and responded with an inconsistent down-link
error message.
1. Do nothing. This error does not affect service.
t. Error Type 3842: LANHO Receive FIFO Overflow error; the packet bus is
delivering data to the ATM-TRK circuit pack faster than the circuit pack can
distribute it to the endpoint.
1. Do nothing. The circuit pack can recover by itself.
u. Error Type 3843: The firmware on the circuit pack is reporting a resource
that is to low. This error does not affect the service and no action is
required.
v. Error Type 3999: circuit pack sent a large number of control channel
messages to the switch within a short period of time.
If
Error Type 1538 is
also present
If Error Type 1538
is not present
System Technician-Demanded Tests:
Descriptions and error codes
Always investigate problems in the order presented. When you clear one of the
error codes associated with a given test, you clear errors generated by other tests
in the testing sequence. If you clear errors out of order, you can lose important
information.
770
Issue 5 October 2002
If
Test #1259 fails with Error Code XXYY and
XX is an AUX value in the preceding table
The system does not recognize the circuit
pack
Then
Circuit pack is taken out of service
Circuit pack is not taken out of service, but has generated 50% of
the messages necessary to be considered hyperactive.
This can be normal during heavy traffic.
If the error is logged during light traffic, it can indicate a problem
with the circuit pack or the equipment attached to it.
Then
Replace the ATM-TRK
circuit pack.
Replace the ATM-TRK
circuit pack.