AN-LN-PT (Analog Line Port)
Battery Feed Test (also called Port Diagnostic
Test) (#35)
The battery feed chip provides power to the telephone equipment, signaling,
rotary dial pulsing, transmission, and balance. This test checks the signaling and
switchhook capabilities of the battery feed chip by terminating the port, applying
battery power, and detecting the resulting current.
Table 52. TEST #35 Battery Feed Test
Error
Test
Code
Result
ABORT
1000
ABORT
1004
ABORT
1005
ABORT
1018
ABORT
555-233-119
Description/Recommendation
Necessary system resources could not be allocated to run this test.
1. Retry the command at 1-minute intervals no more than 5 times.
2. If the test continues to abort, escalate the problem.
System resources are unavailable. The port may be busy with a valid call.
This result is also reported for the system's Music-On-Hold port when it is
off-hook, which it usually is.
1. Use display port UUCSSpp to determine the station's extension.
2. Use status station extension to determine the service state of the
port.
3. If the port is in use, wait until the port is idle. Retry the command at
1-minute intervals no more than 5 times.
4. If the test continues to abort, escalate the problem.
A valid call seized the port during the test and aborted the test.
1. Use display port UUCSSpp to determine the station extension.
2. Use status station extension to determine the service state of the
port.
3. If the port is in use, wait until the port is idle before testing. Retry the
command at 1-minute intervals no more than 5 times.
4. If the test continues to abort, escalate the problem.
This test was aborted due to a configuration problem. The test is not
applicable for this type of analog port. This error can be ignored.
Test has been disabled via administration. The default for the
on the Station screen is y. Determine why this field has been set to
this station. It may be due to application Test #48, which can disturb users
or terminal operations.
1. To enable the test for the station being tested, enter change station
extension and set the
Test
field to y.