Avaya DEFINITY Server CSI Maintenance Manual page 971

Table of Contents

Advertisement

DATA-CHL (Data Channel)
Table 177. TEST #111 Data Channel Local Loop Back Test
Error
Test
Code
Result
4
ABORT
For this test, an Error Code of 4 can have one of two different meanings:
Determine if the target DATA-CHL is in use for some other function (that is,
CDR Link, System Printer Link, Journal Printer Link, PMS Link, or
secondary administration terminal connection) as described previously in
the
that is using the DATA-CHL. If there are no errors, there is a high probability
that the DATA-CHL is not defective. Proceed with the remaining steps only
if it is necessary to completely test the target DATA-CHL.
40
ABORT
Internal system error
70
75
555-233-119
Description/Recommendation
b. The target DATA-CHL is busy and, therefore, not available for use.
c. Internal system error
''Status of Data Channels''
1. If the target DATA-CHL is in use for some other function, busyout the
function (PRI-CDR/SEC-CDR, SYS-PRNT, PMS-PRNT/JNL-PRNT,
PMS-LINK) or the DATA-CHL (secondary administration terminal
connection only).
2. Retry the command at 1-minute intervals a maximum of 5 times.
3. Restore any busied out PRI-CDR/SEC-CDR, SYS-PRNT,
PMS-PRNT/JNL-PRNT, PMS-LINK MOs to service before moving on to
another activity.
1. Retry the command at 1-minute intervals a maximum of 5 times.
section. If so, check for errors on the function