Avaya DEFINITY Server CSI Maintenance Manual page 530

Table of Contents

Advertisement

Maintenance Commands
test alarms
Port
Maintenance On
Name
01C03
UDS1-BD
Port
Maintenance Name
01C03
UDS1-BD
01C03
UDS1-BD
01C03
UDS1-BD
01C03
UDS1-BD
01C03
UDS1-BD
01C03
UDS1-BD
01C03
UDS1-BD
01C03
UDS1-BD
01C03
UDS1-BD
Testing completed for this object.
press CANCEL to quit --
Field descriptions
When encountering errors in preparing a particular object to be tested (not
inserted, contention, etc.), an error message display in the TEST RESULTS
section of the output form.
Port
Maintenance
Name
On Board
Alt Name
Alarm Type
Service State
Ack
Date Alarmed
Alarm Count
530
Issue 5 October 2002
ALARM ENTRY
Alt
Alarm
Brd? Name
Type
n
WARNING
TEST RESULTS
Alt. Name Test No. Result
138
139
140
141
142
143
144
145
146
ALARM ENTRY section
Port location of alarmed object (cabinet-carrier-slot-circuit); same
identifier as alarm log
The name of the maintenance object
Fault detected is on the associated circuit pack (y) or off board
(o).
Terminal extension numbers or trunk group numbers
Major, Minor, or Warning
Current service state of the station and trunk ports: RDY (ready for
service), OUT (out of service), or IN (in service).
Whether alarm has been acknowledged by the first and second
OSS telephone numbers, respectively.
Day, hour, and minute of alarm.
Count of the current alarm entry versus the total number of
alarms to be tested.
Svc
Ack?
Date
State
1 2
Alarmed
03/06/16:48 1/4
NO BOARD
NO BOARD
NO BOARD
NO BOARD
NO BOARD
NO BOARD
NO BOARD
NO BOARD
NO BOARD
press NEXT PAGE to continue
Page
1
Alarm
Count
Error Code
555-233-119

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents